Upfront Septic provided septic pumping and inspection services at a property on Anderson Island, WA, after the homeowner experienced an issue with the pump system alarm. Upon arrival, our technicians found that the pump tank's liquid level was slightly elevated. The homeowner had turned off power to the pump system to silence the alarm.
Our team pumped both the septic tank and the pump tank to remove accumulated wastewater and help restore capacity. Technicians then performed a drawdown test to evaluate pump performance, recording an average drawdown rate of 2.5 inches per minute.
During the inspection, root intrusion was found around the riser serving the second compartment of the septic tank and around the pump tank riser. The conveyance line, which carries wastewater from the septic tank to the pump tank, also appeared to have settled. Although the line was still allowing liquid to flow into the pump tank normally at the time of service, its settled position should be addressed.
Recommended follow-up work includes resealing both affected risers to help prevent further root intrusion and bringing the settled conveyance line back to grade. Installing new risers or extending the existing risers may also be necessary to improve access and properly address the affected areas.
Addressing these concerns can help protect the system from additional root intrusion and support reliable wastewater movement between the septic and pump tanks.
Project Gallery